:DC (?) <%_amplitude> 100,-100,+100
AM OFF | ON | 0 | 1
Purpose
This command turns the AM function on and off
ON or 1 will set the AM on
OFF or 0 will set the AM off
AM?
Response
The 302 will return 1 if the AM is on, or 0 if the AM is off.
APPLy:SINusoid <freq>,<ampl>,<offs>,<phase>
Purpose
This command is a high-level command that programs the 302 to output sine waveform along with its
associated parameters
<freq> numeric which sets the output frequency
<ampl> numeric which sets the output amplitude
<offs> numeric which sets the output offset
<phase> numeric which sets the output start phase
APPLy:SINusoid?
Response
The 302 will return four numerics which represent in order <freq>,<ampl>,<offs>,<phase>.
APPLy:TRIangle <freq>,<ampl>,<offs>,<phase>
Purpose
This command is a high-level command that programs the 302 to output triangular waveform along with its
associated parameters
<freq> numeric which sets the output frequency
<ampl> numeric which sets the output amplitude
<offs> numeric which sets the output offset
<phase> numeric which sets the output start phase
APPLy:TRIangle?
Response to query version
The 302 will return four numerics which represent in order <freq>, <ampl>,<offs>,<phase>.
APPLy:SQUare <freq>,<ampl>,<offs>,<duty_cycle>
Purpose
This command is a high-level command that programs the 302 to output square waveform along with its
associated parameters
<freq> numeric which sets the output frequency
<ampl> numeric which sets the output amplitude
<offs> numeric which sets the output offset