OUTPut:SYNC:POSition <position>
Purpose
This command will program the 302 SYNC position. This command is active in arbitrary (USER) mode only.
<position> will set the SYNC position in waveform points
OUTPut:SYNC:POSition?
Response
The 302 will return the present SYNC position value.
OUTPut:SYNC:WIDTh <width>
Purpose
This command will program the width of the SYNC pulse. This command is active only after PULSe was
selected as the SYNC source.
<width> will set the SYNC width
OUTPut:SYNC:WIDTh?
Response
The 302 will return the present SYNC width value