Field Sweeping with the SDA-5000: Sweepless Sweep
92
4
available (1, 2, 5, and 10 dB/div). Notice what happens to the
display as you change the scale factor. Note the changes to the
display as you change the values.
Press the Level Submenu icon to return to the main REV
ALIGNMENT screen.
Fig. 4-22 REV ALIGNMENT Level Menu
Sweepless sweep allows you to get sweep information even if no transmitter
is available. In Sweepless sweep, the SDA-5000 measures the stable carrier
levels and memorizes them. You can then compare these levels with the
levels of the same carriers at a different point in the network, and the
differences in frequency response can be highlighted.
After connecting to the test point and calculating test point loss as described
in “Test Point Compensation Configuration” (page 60), enter the main
SWEEP menu and use the up and down diamond keys until Sweepless
appears in the Edit Box.
With sweepless sweep selected, the sweep display measures active carriers
to create the sweep response. When sweep is first entered, the first set of
sweep readings will be used as a “NONE” reference. This is just a startup
ach H.E. value
s the level
eceived in the
eadend at the
ndicated
requency (LO
r HI).
Each IN value
represents
the sweep
and telemetry
levels
inserted after
test point
losses.
SWEEPLESS SWEEP