4-17
Diagnostics
Note: If the Diagnostics selection does not appear on the screen, keep
pressing the Down arrow soft key until it scrolls onto the list.
Press the ENTER key to enter the diagnostic mode. The diagnostic
mode allows the user to perform the following functions:
Default to Factory Settings
When this item is selected and the ENTER key is pressed, the unit
will automatically set all parameters to the factory default values.
Warning: All files and references will be lost when resetting the unit
to factory default settings.
Display Test
Allows the user to test the operation of the display. Press the
ENTER key to begin the display test. Follow the instructions
displayed while performing the test.
Transmitter Diagnostics
Press the ENTER key to access the following Transmitter
Diagnostic features:
• Transmitter On/Off - When turned on, provides a CW RF
signal that can be used as a troubleshooting, or installation
aid. The signal is only present when the diagnostic screen
is displayed.
• Transmitter Attenuator - Use the UP and DOWN arrow
keys to enter the amount of attenuation for the CW
transmitted signal.
• Transmitter Frequency - Enter the frequency for the
transmitted signal.