3-3
SCAN: Use the Scan mode to get a good look at absolute carrier
levels. In this mode a bar graph showing all carrier levels is
displayed.
SWEEP:
This mode injects a low level signal in vacant spectrum
areas, and transmits telemetry to any 3SR Receivers that
are connected to the system. Cable system carrier levels in
occupied spectrum areas are monitored and displayed in bar
graph format.
NOTE: Telemetry occurs only while the unit is in Sweep mode.
Selecting another mode will result in a loss of telemetry to
any Receivers connected to the system.
C/N: Measures the C/N (carrier to noise) ratio of the tuned
channel or frequency will be displayed.
HUM: Measures the hum modulation of the tuned channel, will
display in either % or dB as selected by the operator.
MOD: Allows the user to listen to the modulation of the tuned
channel of frequency and measure Depth of Modulation of a
video carrier.
SPECT: Provides a Spectrum Analyzer display, and CSO/CTB
measurements.