WavetekWavetek
WavetekWavetek
Wavetek
CATV Division
5808 Churchman Bypass
Indianapolis, IN 46203-6109
(800)851-1198
(317)788-5960
Fax: (317)782-4607
Internet: http://www.wavetek.com
9/97 Rev. J
Manual Part No.
6510-00-0272
This document contains information proprietary to
Wavetek. The information in this document
is not to be used or duplicated in any manner without
the prior approval, in writing, of Wavetek.
OPERATION MANUAL
MODEL 3SR
SYSTEM SWEEP RECEIVER
Vista de página 0
1 2 3 4 5 6 ... 124 125

Resumo do Conteúdo

Página 1 - MODEL 3SR

WavetekWavetekWavetekWavetekWavetekCATV Division5808 Churchman BypassIndianapolis, IN 46203-6109(800)851-1198(317)788-5960Fax: (317)782-4607E-Mail:

Página 2 - WARRANTY

1-4Sweep Rate: »1 second for 600 MHz sweep, noscrambled channelsAccuracy: + 0.5 dB, normalized (dependent onstability of referenced carriers)Display S

Página 3 - Contents

5-85.2.1 Reverse Sweep Insertion LevelThe reverse sweep can be used to efficiently align the reverse path,while monitoring the frequency response. pro

Página 4

5-9mine the desired input level. For the sweep to arrive at the activedevice input 10 dB below the level of other services in the reversespectrum, sub

Página 5

5-103. Press Enter and highlight Transmitter On/Off.4. Press Up or Down diamond key so ON appears in Edit box.5. Highlight Transmitter Attenuator (0 d

Página 6

5-115.2.3 Forward Telemetry Frequency (3ST)Use the UP and DOWN arrow keys or the numeric keypad to enterthe forward telemetry frequency corresponding

Página 7 - MODEL 3SR

5-125.2.6 Select Sweep DirectionThere are two possible sweep directions on units with the ReverseSweep Option; Forward and Reverse. Use the edit box

Página 8 - 1.2 SPECIFICATIONS

5-135.3 INSTALLATION OF 3ST SWEEP TRANSMITTERProperly connecting the 3ST and setting up the proper levels areperhaps the two most critical steps in i

Página 9 - 1.2.5 Frequency Response

5-14To begin, select a value for DC-B. This allows the video carriers to'hit' the 3ST somewhere in the +10 dBmV range. Additional attenua-ti

Página 10 - 1.2.7 Telemetry

5-155.4 FIELD TEST POINT CONSIDERATIONSThe same basic rules apply to the 3SR/3SRV. Too much signal levelon the input of the unit can cause inconsiste

Página 11 - 1.2.8 Spectrum Mode

5-16the forward telemetry frequency from the 3HRV and the forwardtelemetry frequency from the 3ST, your receiver does not have theproper version of f

Página 12 - 1.2.13 Powering

5-175.6 REVERSE INGRESS FEATUREWith a model 3SR with 3SRV option, the operator may at any timerequest a view of the headend reverse path ingress spect

Página 13 - 1.2.16 Optional Accessories

1-51.2.8 Spectrum ModeSpans: 3, 5, 10, 20, and 50 MHz (0.3, 0.5, 1, 2, and5 MHz/div)Sweep Rates: 1 second (5 MHz)2 seconds (10, 20 & 50 MHz)Displa

Página 14

5-185.7 REVERSE SWEEP OPERATIONAll softkeys and controls work identically whether you are Forward orReverse sweeping.The icons at the bottom of the sw

Página 15 - SECTION 2 INSTALLATION

5-195.7.2 Changing the Sweep DirectionThe sweep direction can be selected using the “Sweep Receiver”setup screen as described earlier. You can also c

Página 16 - 2.5 CABLE SPECIFICATIONS

5-20upon what has been selected in setup.5.7.5 Forward and Reverse Sweep ReferencesReverse sweep references are stored and selected the same asForward

Página 17 - Serial Printer Cable

5-215.7.7 Recognizing 3SR in Reverse Sweep OptionYou can tell if a 3SR has the Reverse Sweep option by looking at thestatus screen.NOTE: To view the s

Página 18 - 2.7 Worldwide Sales Offices

5-225.8 CPD (Common Path Distortion) ANALYSISTest Equipment / Procedure RecommendationsDescription of CPD and CausesCPD (Common Path Distortion) is a

Página 19 - SECTION 3 USER INTERFACE

5-23getting close is the white powder that is a symptom of oxidation ofaluminum housings; often aluminum darkens when oxidation istaking place. These

Página 20

5-24Figure 5. Common path distortion appears as beats at regularintervalsRecommended Setup for CPD AnalysisIf the test point is not band-limited to th

Página 21

5-25both forward and reverse signals present. This phenomenon maypresent itself when performing a reverse noise test using the StealthModel 3ST trans

Página 22 - 3.2.4 Arrow Keys

A-1APPENDIX A STATUS INDICATORS/ICONS INTRODUCTIONThere are numerous status indicators/icons displayed on the Stealth3SR. The following is a list of a

Página 23 - 3.2.6 Printing

B-1APPENDIX B USER MESSAGES INTRODUCTIONThere are numerous user messages that will appear on the unit. Somemessages can be caused by improper operatio

Página 24 - 4.1 INTRODUCTION

1-61.2.10 Depth of ModulationAssumes presence of white reference on any VITS line. Non-scrambled channels only.Range: 80 to 100%Resolution: <0.5% a

Página 25

B-2Message ERROR... Insufficient signal level to perform themeasurement!Condition A minimum carrier level is requiredfor C/N and HUM measurements.Resp

Página 26 - 4.3 SETUP

B-3Message ERROR... The selected reference has beencorrupted!Condition The reference cannot be usedbecause of a non-volatilememory failure.Response De

Página 27 - 4.3.1 General Setup

B-4Message SORRY... There is not enough memory to store anew file!Condition Memory is currently at maximumcapacity.Response Delete unwanted files to m

Página 28

B-5Message SORRY... The active plan cannot be deleted!Condition An attempt to delete the activechannel plan.Response Select a different plan as the ac

Página 29

B-6Message SORRY... The last channel cannot be deleted!Condition An attemp was made to delete thelast channel of a plan.Response A channel plan must c

Página 30

B-7Message ERROR... C/N cannot be measured on a scrambledchannel!Condition A channel that has beenprogrammed as scrambled insetup has been selected in

Página 31 - 4.3.2 Measurements Setup

1-71.2.14 Standard AccessoriesSoft Carrying CaseField replaceable Battery CartridgeBattery Charger/AC Adapter(2) "F" type input connectorsOp

Página 32

1-8PP-220-440 Tunable Precision Preselector (220 to 440 MHz)PP-440-880 Tunable Precision Preselector (440 to 880 MHz)7201 Tunable Precision Preselecto

Página 33

2-1SECTION 2 INSTALLATION2.1 INTRODUCTIONThe Wavetek Model 3SR Receiver is a rugged piece of precision testequipment designed for portability. It is w

Página 34

2-22.5 CABLE SPECIFICATIONSThere are two cables associated with the operation of the 3SRReceiver; Stealth to Stealth (sent with 3ST Transmitter), and

Página 35

2-3Serial Printer CableThe Serial Printer Cable, (1217-50-0151) can be used to print datadirectly from the 3SR Receiver.TxRxGNDDTRRxTxDTRGNDDSRCTS

Página 36

2-42.6 TECHNICAL SUPPORTWe've worked hard to make the 3SR as easy-to-use as possible If youhave a problem using your unit you can contact Wavetek

Página 37

3-1SECTION 3 USER INTERFACE3.1 INTRODUCTIONThis section will help you become familiar with the front-panelcontrols of the Model 3SR Receiver. Included

Página 38

WARRANTYWavetek warrants that all Products manufactured or procured by Wavetek conform toWavetek’s published specifications and are free from defects

Página 39

3-23.2.2 Measurement Mode Selection KeysMeasurement modes are chosen by pressing the appropriate Mea-surement Mode Selection key. There is a key for

Página 40

3-3SCAN: Use the Scan mode to get a good look at absolute carrierlevels. In this mode a bar graph showing all carrier levels isdisplayed.SWEEP:

Página 41

3-4Setup: The setup functions are used to set or adjust the operatingparameters of the unit.3.2.4 Arrow KeysThe four Arrow keys are used for various p

Página 42 - 4.3.5 Sweep Receiver

3-5123 - numeric entry mode - multiple choice modeAlpha Entry ModeMost numeric keys have alphabetic characters printed on them.These characters can be

Página 43

4-1SECTION 4 OPERATION - HOW TO USE THE 3SR RECEIVER4.1 INTRODUCTIONThis section provides detailed operation of the Model 3SR Receiver.Included are de

Página 44

4-25. You will then be prompted to enter the highest frequency that youwould like to scan. Type in the frequency and press the ENTERkey followed by th

Página 45

4-3The parameters for each channel may be edited by cursoring to thechannel to be edited and pressing the Edit soft key.Check the listed channels to e

Página 46

4-44.3.1 General SetupUse the Up and Down soft keys to scroll to additional setup items.When lists are being displayed, the up arrow soft key dims whe

Página 47

4-5Operator NameAllows the user to enter the operators name. The name will appear inthe header section of the Auto Test report.Contrast LevelAdjusts t

Página 48

4-6Date FormatUse the UP and DOWN arrow keys to select the desired date format.When the date format is changed, the new format will appear every-where

Página 49 - 4.6 SCAN MODE

ContentsSECTION 1 - GENERAL INFORMATION1.1 INTRODUCTION ... 1-11.2 SPECIFICATIONS ...

Página 50

4-7BeepsThe 3SR Receiver produces beeps to alert you of certain operatingconditions.The arrow keys are used to turn Beeps on or off as desired.Diagnos

Página 51

4-8• Transmitter Frequency - Enter the frequency for thetransmitted signal.Warning: Subscriber interference could result, if the frequency is setto a

Página 52

4-9Test Point CompensationTest Point Compensation is used to account for loses associated withcertain amplifiers. Use the UP and DOWN arrow keys or th

Página 53 - 4.7 HOW TO MEASURE C/N

4-10C/N CalibrationTo increase the accuracy of the C/N measurements, a noise floorcalibration is performed. This allows the user to characterize theno

Página 54 - • Noise frequency

4-11Select Channel PlanPress the ENTER key to call up a list of existing channel plans. If theunit is being used for the first time, the only Channel

Página 55 - 4.8 HOW TO MEASURE HUM

4-12Build Channel PlanPress the ENTER key to begin the Build Channel Plan sequence.This sequence allows the user to create a channel plan by "lea

Página 56

4-13Use the Up or Down arrow soft keys to select the channel that youwish to edit.Press the Edit soft key to view and edit the following parameters:No

Página 57 - 4.9 MODULATION

4-14EnabledY/N - If the channel is not enabled it will not be included in anymeasurement mode. At least one channel must be enabled.Channel TypeTV - I

Página 58 - 4.10 SPECTRUM ANALYZER MODE

4-15Sweep ChannelY/N - Designates that the channel will be used for Sweepmeasurements.Measurement Bandwidth AdjustmentsTo edit the bandwidth, cursor t

Página 59

4-16Audio Offset 2Specifies the offset for the second audio carrier of a Dual typechannel.An ADD and DELETE soft key allows for adding new channels to

Página 60

2.7 Worldwide Sales Offices ...2-4SECTION 3 - USER INTERFACE3.1 INTRODUCTION ...

Página 61

4-17Use the Up and Down arrow soft keys to cursor to a channel. Use theC/N, HUM, and MOD soft keys to select the desired Auto Testmeasurements.Note: C

Página 62

4-18The Edit Limits function works in conjunction with the performanceof an Auto Test. As the Auto Test measurements are made, thevalues are compared

Página 63 - 4.11.1 Introduction

4-194.3.5 Sweep ReceiverSweep ModeUse the UP and DOWN arrow keys to select the desired sweepmode.Sweep Limit VariableThe sweep limit variable is used

Página 64 - 4.11.2 Operation

4-20Forward Telemetry Frequency (3ST)Use the UP and DOWN arrow keys or the numeric keypad to enterthe forward telemetry frequency corresponding to the

Página 65

4-21Sweep Direction (3SRV Models in Stealth mode only)There are two possible sweep directions on units with the ReverseSweep Option; Forward and Rever

Página 66

4-22Sweep File OverlaySweep file overlay allows a stored sweep response to be viewedsimultaneously with the "live" sweep response for direct

Página 67 - 4.12 FILE

4-23Information displayed in the Level mode is as follows: Label (up to four characters)• Channel number or frequency• Channel label• Video c

Página 68

4-24• Test point compensation (appears only if a nonzero value is programmed during setup) - used to eliminate the test point loss or probe loss f

Página 69

4-254.5 HOW TO MEASURE TILT - BALANCING AN AMPLIFIERA cable system is designed for unity gain, and the output of each liketype of amplifier (trunk, br

Página 70 - 4.12.3 Sweep File Overlay

4-26Information displayed in the Tilt mode is as follows :• High and low carrier frequencies• High and low carrier levels• Tilt measurement• Reference

Página 71 - 4.13 AUTO

4.10 SPECTRUM ANALYZER MODE ... 4-354.11 HOW TO PERFORM SWEEPMEASUREMENTS...

Página 72

4-27Information displayed in the Scan mode is as follows:• Channel number• Channel label• Video carrier frequency and level (numerical)• Audio carrier

Página 73

4-28Level AdjustmentsPress the LVL soft key to edit the scale and reference level of theScan display. To adjust the Scale, use the UP and DOWN arrow k

Página 74

4-29Scan RateTwo scan rates are available in the Scan mode, normal and fast. Thescan rate is selected in the Measurement Setup menu. The Fast scanfeat

Página 75

4-30An "aggregate" result summary can be accessed by pressing the LIMsoft key. This performs a limit check of all channels contained withint

Página 76

4-31In the C/N mode the carrier to noise ratio of the tuned channel orfrequency is displayed. The C/N measurement bandwidth and thefrequency offset fo

Página 77

4-32NOTE: If the C/N measurement value is outside the specified range,the numerical result will change from black to gray.To edit the bandwidth, press

Página 78

4-33before performing an Auto test. Once the Auto Test is performed,the units cannot be changed for that particular test. Soft keys allowthe operator

Página 79

4-34Note: The <1kHz setting does not include the 1Hz component, it onlyincludes 50 to 1000Hz. Information displayed in the Hummode is as follows:NO

Página 80

4-354.10 SPECTRUM ANALYZER MODEThe spectrum analyzer display provides a view of the system spec-trum with variable spans from 50 MHz to 3 MHz and a dy

Página 81

4-36Level AdjustmentsA LVL (level) soft key is used to adjust the vertical parameters of thegraph. These parameters include Max Hold, Ref Level and Sc

Página 82

5.3 INSTALLATION OF REVERSE SWEEP TRANSMIT-TER ... 5-135.4 FIELD

Página 83

4-37How To Make FCC In-Channel Response Measurements(FCC limit: < + 2 dB)The frequency response of any channel can be measured using thespectrum an

Página 84

4-38Press the OK soft key once the carrier has been turned off. TheCSO/CTB measurement is now displayed.

Página 85

4-39The light trace represents the carrier prior to it being turned off. Thedark trace represents the distortion products. The measurementvalue is com

Página 86

4-40Using the Up and Down arrow soft keys, select the CSO Offsetnumber to change. Use the numeric entry keys or the UP and DOWNarrow keys to enter a n

Página 87

4-414.11.2 OperationFrequency AdjustmentsThe FRQ (frequency) soft key is used to set the start and stopfrequency. A start and stop soft key is display

Página 88

4-42graph. These parameters include Ref Level and Scale. The referencelevel is the midpoint level displayed on the graph. The Ref Levelcan be adjusted

Página 89

4-43adjust limits, and specify the amp number. If the limits function isoff, the adjust limits and amp number soft keys are disabled anddimmed. The li

Página 90

4-44indicator appears in the upper portion of the sweep screen.The tilt compensation feature allows the user to enter the cable lossfor a particular s

Página 91 - 4.14 STATUS

4-45selected, press the View soft key. Scan measurements can be stored,but can only be viewed/printed using the Stealthware Data Analysissoftware. Onc

Página 92

4-464.12.2 How to Store/Delete Sweep ReferencesThe Sweep References soft key allows the user to select, store ordelete sweep references. After a sweep

Página 93 - 5.1 INTRODUCTION

1-1SECTION 1 GENERAL INFORMATION1.1 INTRODUCTIONThe Wavetek hand-held System Sweep Receiver performs essentialcable TV system preventive maintenance t

Página 94

4-47Sweep mode, and the default reference will be used. It is recom-mended that obsolete references be deleted in order to free memoryfor additional r

Página 95

4-48The stored sweep response is displayed as a gray-filled area. The liveresponse appears as a solid line superimposed or overlaid on top ofthe store

Página 96

4-494.13.1 How To Create/Edit/Delete Test LocationsTest Locations allow the user to create specific test point locationparameters used in the Auto Tes

Página 97

4-50Press the New soft key to create a new Test Location file.The unit will then prompt for a file name. Once a name is entered,press the OK soft key

Página 98 - 5.2 REVERSE SWEEP SETUP

4-51Each location in the list has an associated type and values for thedescriptive parameters. The parameters are shown in the followingtable.Paramete

Página 99

4-52Characteristic Trunk Head Extender Fiber Field1 Area yes yes yes yes2 Amp Id yes yes yes3 Power Configuration yes yes yes4 Feeder Maker Config y

Página 100

4-53Auto Test LocationUsing the Up and Down arrow keys, select an Auto Test location.Select NONE if location information is not desired. Press the OK

Página 101

4-54Auto Test CharacteristicsUse Up and Down arrow keys to scroll through the location character-istics for the test being performed. Press the ENTER

Página 102

4-55Test Point TypeUse the Up and Down arrow keys to select the Test Point type.When the desired Test Point type is selected, press the OK soft key.Th

Página 103

4-56Voltage MeasurementsUse the numeric entry keys to enter the following system voltagemeasurements:• AC Voltage• DC Voltage (regulated)• DC Voltage

Página 104 - 5.2.6 Select Sweep Direction

1-2The 3SR Receiver, in addition to performing its sweep receptionduties, conducts a battery of signal level measurements, including afull scan of the

Página 105

4-57Test Point CompensationTest Point Compensation is used to account for loses associated withcertain amplifiers. Use the UP and DOWN arrow keys or t

Página 106

4-58Results FileEnter a file name for the Auto Test results to be stored. If an existingfile name is used, a warning message will appear prompting the

Página 107 - SWEEP TESTING

4-59While the Auto Test is in progress, the following screen is displayed:While the Auto Test is in progress, the measurement currently beingperformed

Página 108

4-60Using the numeric entry keys, enter the start and stop information forthe date and time as well as the interval amount. Press the ENTERkey after e

Página 109 - 5.6 REVERSE INGRESS FEATURE

4-61When the unit is between testing intervals it will enter a sleep modein order to conserve battery life. All other unit functions are disableddurin

Página 110 - 5.7 REVERSE SWEEP OPERATION

4-62A table with all testing intervals and test site information is nowdisplayed. If the Auto Test was performed immediately, then onlyone interval is

Página 111 - 5.7.3 Reverse Noise Feature

4-63Information provided on each interval includes:• Interval number• Date measurement was made• Time measurement was made• Temperature• Pass/Fail tes

Página 112

4-64-------------------------------------------------------------------------WAVETEK STEALTH 24 HOUR TEST REPORTModel: 3SR Serial No:

Página 113

4-65The channels with the asterisks indicate those channels that ex-ceeded the Max Delta Adjacent Channels limit. The limits that thereadings were com

Página 114

4-66• < under range• > over range• E synthesizer unlockedUse the More soft key to toggle between Level measurements, C/N,Hum, and Modulation mea

Página 115

1-31.2.3 Hum Measurement(carrier > 0 dBmV) Non-scrambled channels onlyRange: 0 to 10%Resolution: <0.2%Accuracy: +0.7%1.2.4 Carrier to Noise Meas

Página 116

4-67-------------------------------------------------------------------------WAVETEK STEALTH AUTO TEST REPORTModel: 3SR Serial No: 12

Página 117 - Instrument

4-684.14 STATUSTo view the Status screen, press the FCN key followed by the Statussecond function key. The Status screen provides unit information tot

Página 119 - APPENDIX B USER MESSAGES

5-1SECTION 5 REVERSE SWEEP OPTION5.1 INTRODUCTIONThe Stealth sweep system is designed to be non-interfering. Hencethe name Stealth for something that

Página 120

5-2With the reverse sweep option, a transmitter is built into the hand-held sweep receiver. The headend sweep transmitter (3ST/3HRV) isset up to rece

Página 121

5-3fier is aligned such that the response at the headend is within certainlimits from this amplifier alignment point. So, in the reverse path theampli

Página 122

5-4Figure 2. Single Cable - Split Band Network Reverse SweepConfiguration With Directional Test Points.Another common architecture, which is only slig

Página 123

5-5Figure 3. Transmitter Connections In Headend For Hybrid Fiber/CoaxNetworksFigure 4. Fiber Node Test Point ConnectionsDual Cable NetworkAnother poss

Página 124

5-6The problem is that the two systems use the same spectrum,making it impossible to distinguish between the two with oneinstrument.The recommended me

Página 125

5-7The peak held spectrum scan shown in figure below is an example ofa fully-loaded reverse band. Services carried include: telephony, data(cable mode

Comentários a estes Manuais